Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.autonoma.edu.co/handle/11182/1287
Título : Alternativas al formol como fijador y conservador de estructuras y tejidos en los laboratorios de patología
Autor: Hoyos Santos, Lorena Beatriz
Director(es): Álzate Mejía, Oscar Andrés
Palabras claves: Anatomía
Patología
Formaldehido
Fijación
keywords: Anatomy
Pathology
Formaldehyde
Fixation
Editorial : Universidad Autónoma de Manizales
Resumen: El formaldehído ha sido catalogado como una sustancia con propiedades tóxicas, cancerígenas y mutagénicas donde su principal vía de ingreso al cuerpo es por el sistema respiratorio, causando irritación y afecciones crónicas que incluso derivan en cáncer. La presente investigación se centró en evaluar diferentes alternativas al formol como fijador y conservador de piezas anatómicas para el estudio histopatológico en los laboratorios de patología. Lo anterior enmarcado en la necesidad de establecer el uso de herramientas y compuestos que sean amigables con el medio ambiente y la salud de los profesionales. La investigación es de diseño cuasi-experimental. El procedimiento tuvo una duración de 28 días, realizando mediciones en los días 1, 5, 7, 14, 21 y 28, siguiendo el diseño propuesto por Wolff et al., (13), dichas mediciones permitieron medir la capacidad de fijación de las sustancias usadas como también evaluar la calidad de la conservación para el diagnóstico. Como principales resultados se encontró bajas variaciones en cuanto al color y la consistencia de las muestras, manteniendo el color natural y la consistencia normal. Al finalizar de todo el experimento se hizo la respectiva evaluación de la calidad de la tinción para el diagnóstico, siendo excelente en las sustancias usadas.
Abstract: Formaldehyde has been classified as a substance with toxic characteristics, carcinogenic and mutagenic characteristics where its main route of entry into the body is through the respiratory system, causing irritation and chronic conditions that could even lead to cancer. The current research was focused on evaluating different alternatives to formalin as a fixative and preservative of anatomical pieces for histopathological studies in pathology laboratories. This is framed in the need to establish the use of tools and compounds that are friendly to the environment and the health of professionals. The research is of quasi-experimental design. The procedure lasted 28 days, taking measurements on days 1, 5, 7, 14, 21 and 28, following the design proposed by Wolff et al. (13). These measurements allowed measuring the binding capacity of the substances used as well as evaluating the quality of conservation for diagnosis. The main results were low variations in the color and consistency of the samples, maintaining the natural color and normal consistency. At the end of the experiment, the respective evaluation of the quality of the staining for diagnosis was made, being excellent in the substances used.
URI : https://repositorio.autonoma.edu.co/handle/11182/1287
Aparece en las colecciones: Maestría en Biología Humana

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Alternativas_Formol_Fijador_Conservador_Estructuras.pdfTexto completo3,28 MBAdobe PDFVista previa
Visualizar/Abrir
Auto_Alternativas_Formol_Fijador_Conservador_Estructuras.pdfAutorización45,82 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons