Title: Efecto del termoformado sobre la deformación en posiciones dentales de alineadores plásticos usados en ortodoncia
Authors: Álvarez Castro, Juan David
Advisor: Álvarez Vargas, César Augusto
Orozco Ocampo, Yenny Marcela
Keywords: Termoformado
Alineadores Dentales
Deformación
Espesor
Keywords: Thermoforming
Dental Aligners
Deformation
Thickness
Publisher: Universidad Autónoma de Manizales
Abstract(esp): Determinar la influencia del termoformado sobre las deformaciones de un alineador dental. El presente proyecto de investigación plantea un tipo de estudio descriptivo – correlacional con un diseño metodológico experimental, en el análisis de las variables geométricas que influyen en el desempeño clínico de alineadores dentales de PET – G. Para lo cual se termoformaron 20 alineadores PET-G a presión positiva con un espesor inicial de 0,76 mm y 1,02mm, los cuales mediante un calibrador digital modificado, microscopio digital PCE WSM 10 y software ProScope permitieron determinar las medidas de las deformaciones sobre el alineador según del método propuesto. Los resultados obtenidos, fueron validados bajo una análisis estadístico en el software SPSS v. 26 como la formulación de ecuaciones para la correlación de las deformaciones sobre las posiciones dentadas. modelación de ecuaciones para las dos variables dependientes espesor y deformación, con valores de aceptación del 57,1% y 42,7% respectivamente. Los valores mínimos de espesor final y máximos de deformación se obtuvieron con muestras de espesor inicial de 1,02mm. La mayor de deformación se obtuvo con una muestra del canino con valor de 7,786mm para un espesor de 1,02mm. En contraste, la medida con menor espesor final para los 4 tipos de dientes descritos se obtuvo con una muestra del primer incisivo 0,45mm para un espesor inicial de 1,02mm, representando una reducción del 44% de su espesor.
Abstract(eng): To determine the influence of thermoforming on the deformations of a dental aligner. This research project proposes a type of descriptive - correlational study with an experimental methodological design, in the analysis of the geometric variables that influence the clinical performance of PET - G dental aligners. For which 20 PET-G aligners were thermoformed at positive pressure with an initial thickness of 0.76 mm and 1.02 mm, which by means of a modified digital caliper, PCE WSM 10 digital microscope and ProScope software allowed to determine the measurements of the deformations on the aligner according to the proposed method. The results obtained were validated under a statistical analysis in the SPSS v. 26 as the formulation of equations for the correlation of the deformations on the tooth positions. modeling of equations for the two dependent variables thickness and deformation, with acceptance values of 57.1% and 42.7% respectively. The minimum final thickness and maximum deformation values were obtained with samples with an initial thickness of 1.02mm. The greatest deformation was obtained with a sample of the canine with a value of 7.786mm for a thickness of 1.02mm. In contrast, the measurement with the lowest final thickness for the 4 types of teeth described was obtained with a 0.45mm sample of the first incisor for an initial thickness of 1.02mm, representing a 44% reduction in thickness.
URI: https://repositorio.autonoma.edu.co/handle/11182/1374
Appears in Collections:Maestría en Ingeniería